Features:
1. The software supports automatic potential tracking correction to ensure stable performance.
2. Automatic monitoring and filtering of tiny air bubbles to ensure measurement accuracy.
3. Wave flushing and pipeline flushing can avoid blockage and cross-contamination.
4. Power-off protection, can protect data storage, the result can be stored up to 50,000.
5. Low consumption, effectively reducing the cost of consumables.
6. 7-inch high-definition touch screen, comprehensive content display.
7. With the function of automatic fault alarm and elimination, improve work efficiency.
Technical Parameters:
Model | BKE-A, BKE-B, BKE-C, BKE-D | BKE-E, BKE-F, BKE-L |
Sample | Serum, plasma, whole blood, cerebrospinal fluid and dilute urine | |
Measuring Speed | ≤25s | |
Analysis Method | Ion selective electrode(ISE) | |
Sample Volume | 60~150μl | 200μl |
Sample Position | 30 sample positions, 5 emergency positions(Only for BKE-B/D/F/L) | |
Injection mode | Manual or automatic injection can be selected(Only for BKE-B/D/F/L), BKE-A/C/E is manually injection | |
Storage | Up to 50,000 test results | |
Printer | Build-in thermal printer | |
Interface | RS232 port for LIS | |
Display | 7-inch high-definition touch screen | |
Language | Chinese and English, other languages can be customized | |
Calibration | Automatic and Manual calibration | |
Other Function | Sample volume detection | |
Power Supply | AC100~240V, 50/60Hz, 70VA | |
Temperature | +10~+40℃ | |
Relative Humidity | ≤80 % | |
Atmospheric Pressure | 86~106kPa |
Model | BKE-A | BKE-B | BKE-C | BKE-D |
Test Items | K+, Na+, Cl- | K+, Na+, Cl- | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH |
Sample Tray | No | Yes | No | Yes |
External Size(W*D*H)(mm) | 405*214*471 | 682*287*471 | 405*214*471 | 682*287*471 |
Net Weight(kg) | 12.48 | 15.11 | 12.48 | 15.11 |
Package Size(W*D*H)(mm) | Instrument: 500*390*530 Reagent: 220*160*120, 220*160*120 | Instrument: 500*390*720 Reagent: 220*160*120, 220*160*120 | Instrument: 500*390*530 Reagent: 220*160*120, 220*160*120 | Instrument: 500*390*720 Reagent: 220*160*120, 220*160*120 |
Gross Weight(kg) | Instrument: 16.08 Reagent: 1.7, 0.9 | Instrument: 19.31 Reagent: 1.7, 0.9 | Instrument: 16.08 Reagent: 1.7, 0.9 | Instrument: 19.31 Reagent: 1.7, 0.9 |
Model | BKE-E | BKE-F | BKE-L |
Test Items | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG | K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG, Li+, Mg2+ |
Sample Tray | No | Yes | Yes |
External Size(W*D*H)(mm) | 405*214*471 | 682*287*471 | 682*287*471 |
Net Weight(kg) | 13.13 | 15.76 | 15.76 |
Package Size(W*D*H)(mm) | Instrument: 500*390*530 Reagent: 280*135*210, 220*160*120 | Instrument: 500*390*720 Reagent: 280*135*210, 220*160*120 | Instrument: 500*390*720 Reagent: 280*135*210, 220*160*120 |
Gross Weight(kg) | Instrument: 16.73 Reagent: 2.2, 1.2 | Instrument: 19.96 Reagent: 2.2, 1.2 | Instrument: 19.96 Reagent: 2.2, 1.2 |
Items | Measuring Range | Resolution |
K+ | 0.5~20.0mmol/L | 0.01mmol/L |
Na+ | 15~200mmol/L | 0.01mmol/L |
Cl- | 15~200mmol/L | 0.01mmol/L |
Ca2+ | 0.1~6.0mmol/L | 0.01mmol/L |
pH | 4~9 | 0.01 |
TCO2 | 2.0~70.0mmol/L | 0.1mmol/L |
Li+ | 0.1~6.0mmol/L | 0.01mmol/ L |
Mg2+ | 0.1~4.0mmol/L | 0.01mmol/ L |
Product Name | Reagent for Electrolyte Analyzer(ISE) |
Component | Drift correction solution A(350ml) Slope correction solution B(350ml) Reference solution(10ml*2) Filling solution in electrode(3ml) Cleaning fluid E(100ml) Electrode activation fluid(100ml) Internal correction solution(100ml) Electrode cleaning fluid(protease): Protease: 25mg*5; Diluent: 5ml*1 Drift correction solution(CO2 standard 1): 100ml*1(only for BKE-E/F/L) Slope correction solution(CO2 standard 2): 100ml*1(only for BKE-E/F/L) CO2 acidic washing: 100ml*1(only for BKE-E/F/L) |
Precision | TCO2, Mg2+ repeatability CV≤3.5%; Batch variations R≤5% iCa2+, Li+ repeatability CV≤1.5%; Batch variations R≤3% Others repeatability CV≤1.5%; Batch variations R≤2% |
Accuracy | K+, Na+, Cl-, pH relative deviation≤±3.0% iCa2+, Li+ , Mg2+ relative deviation≤±5%, or≤±0.05mmol/L TCO2 relative deviation≤±5% |
Linearity | r≥0.995 |
Package Size(L*W*H)mm | Commodity inspection reagent: 220*160*120(only for BKE-A/B/C/D), 280*135*210(only for BKE-E/F/L) Non-commodity inspection reagent: 220*160*120 |
Gross Weight(kg) | Commodity inspection reagent: 1.7(only for BKE-A/B/C/D), 2.2(only for BKE-E/F/L) Non-commodity inspection reagent: 0.9(only for BKE-A/B/C/D), 1.2(only for BKE-E/F/L) |