| Availability: | |
|---|---|
| Quantity: | |
ZS-AE7S
BIOBASE
Features:
Technical Parameters:
Model | ZS-AE7S |
Laser | 488nm solid(60mW) |
Detector | FSC, SSC, FL1-FL5 |
Fluorescence Channel | FL1:525/50(FITC) FL2:585/40(PE) FL3:630/30(PE-Texas Red/ECD/PI) FL4:697/60(PerCP/PE-Cy5/PE-Cy5.5) FL5:780/60(PE-Cy7) |
Fluorescence Sensitivity | FITC≤50 MESF, PE≤30MESF |
Fluorescence Linearity | ≥0.99 |
FSC Sensitivity | ≤1μm |
Test Particle Size | 0.2~50μm |
Carry Over | ≤0.5% |
Instrument CV | FSC and all FL channel CV less than 2% |
FSC and SSC CV | Can separate red blood cells and platelet, can separate white blood cells into 3 groups |
Test Speed | ≥46000 cells/s |
Minimum Sample Vol | 90μL |
Measure Range | Maximum Support 10⁷ |
Threshold | Double threshold, minimum cells fraction |
Fluorescence Compensation | Support auto online compensation, offline compensation and visualized compensation |
Item Template | Support Item template, acquisition conditions/fluorescence compensation one-click use |
Intake Method | Manual intake Rotary wheel auto-sampling with auto-mixing function:32tests/wheel |
Liquid Storage Station | Sheath bottle, waste bottle, shutdown liquid bottle 2L, cleaning liquid bottle 0.5L |
Software | English/Chinese |
PC | Dell(CPU i5/8G DDR4/1T hard disk)+Dell 27 inches monitor |
Power Supply | AC220/110V±10%, 50/60Hz |
Optional | Auto-sampler |
External Size(W*D*H) | 430*500*330mm 650*500*330mm(with autosampler) |
Net Weight | 30kg 35kg(with autosampler) |
Packing Size(W*D*H) | Main Instrument: 860*635*648mm Accessories: 860*680*810mm Reagent: 405*270*400mm |
Gross Weight | Main Instrument: 56kg Accessories: 54kg Reagent: 16kg |
Features:
Technical Parameters:
Model | ZS-AE7S |
Laser | 488nm solid(60mW) |
Detector | FSC, SSC, FL1-FL5 |
Fluorescence Channel | FL1:525/50(FITC) FL2:585/40(PE) FL3:630/30(PE-Texas Red/ECD/PI) FL4:697/60(PerCP/PE-Cy5/PE-Cy5.5) FL5:780/60(PE-Cy7) |
Fluorescence Sensitivity | FITC≤50 MESF, PE≤30MESF |
Fluorescence Linearity | ≥0.99 |
FSC Sensitivity | ≤1μm |
Test Particle Size | 0.2~50μm |
Carry Over | ≤0.5% |
Instrument CV | FSC and all FL channel CV less than 2% |
FSC and SSC CV | Can separate red blood cells and platelet, can separate white blood cells into 3 groups |
Test Speed | ≥46000 cells/s |
Minimum Sample Vol | 90μL |
Measure Range | Maximum Support 10⁷ |
Threshold | Double threshold, minimum cells fraction |
Fluorescence Compensation | Support auto online compensation, offline compensation and visualized compensation |
Item Template | Support Item template, acquisition conditions/fluorescence compensation one-click use |
Intake Method | Manual intake Rotary wheel auto-sampling with auto-mixing function:32tests/wheel |
Liquid Storage Station | Sheath bottle, waste bottle, shutdown liquid bottle 2L, cleaning liquid bottle 0.5L |
Software | English/Chinese |
PC | Dell(CPU i5/8G DDR4/1T hard disk)+Dell 27 inches monitor |
Power Supply | AC220/110V±10%, 50/60Hz |
Optional | Auto-sampler |
External Size(W*D*H) | 430*500*330mm 650*500*330mm(with autosampler) |
Net Weight | 30kg 35kg(with autosampler) |
Packing Size(W*D*H) | Main Instrument: 860*635*648mm Accessories: 860*680*810mm Reagent: 405*270*400mm |
Gross Weight | Main Instrument: 56kg Accessories: 54kg Reagent: 16kg |
Download:
Flow Cytometer ZS-AE7S.jpg
Download:
Flow Cytometer ZS-AE7S.jpg