| Availability: | |
|---|---|
| Quantity: | |
BKC-TL5M
BIOBASE
Features:
1. Embedded microprocessor control, push-button programming.
2. Can store and recall 20 sets of operating programs.
3. Support speed 1rpm and time 1s fine-tuning; power-down self-recovery.
4. Adjustable parameters during operation, convenient and quick.
5. 10 lifting rates to choose from, fast lifting speeds.
6. Equipped with program memory function, automatically retains the parameters from the last run and automatically restores the set parameters before shutdown.
7. Automatic door opening and alert when centrifugation is complete.
8. Multi-stage shock absorption, multiple protection for over-speed, imbalance and door cover.
Technical Parameters:
Model | BKC-TL5M |
Max Speed | 5000rpm |
Max RCF | 4390×g |
Max Capacity | 2000ml |
Speed Precision | ±20rpm |
Timing Range | 1s~999min |
Noise | ≤70dB |
Consumption | 550W |
Power Supply | AC110~220V, 50/60Hz |
External Size(W*D*H) | 620*450*350mm |
Package Size(W*D*H) | 765*595*632mm |
Net Weight | 45kg |
Gross Weight | 60kg |
Rotor:
No. | Rotor | Capacity | Max. Speed(rpm) | Max. RCF(×g) | Adapter |
No.1 | Swing Rotor Support | 4*500ml | / | / | / |
Hanging Cup | 4*500ml | / | / | / | |
Adapter | 4*250ml | 4000 | 3023 | / | |
4*2*100ml | 3023 | / | |||
4*100ml(▲) | 3023 | / | |||
4*100ml | 3023 | / | |||
4*3*50ml | 3023 | / | |||
4*2*50ml | 3023 | / | |||
4*50ml | 2808 | / | |||
4*4*30ml PP tube | 2808 | / | |||
4*9*15ml | 2808 | / | |||
4*8*15ml(▲) | 2808 | / | |||
4*8*15ml | 2808 | / | |||
4*12*10ml | 3184 | / | |||
4*12*5ml blood collection tube | 2808 | 48*2ml | |||
Tube Rack | 4*16*10ml | 4000 | 2810 | / | |
4*20*7ml PP tube | 3139 | / | |||
4*24*5ml blood collection tube(106mm) | 3032 | 96*2ml | |||
4*24*5ml blood collection tube(100mm) | 3032 | 96*2ml | |||
4*20*5ml blood collection tube(106mm) | 3050 | 80*2ml | |||
4*24*2ml blood collection tube | 2585 | / | |||
4*20*2ml blood collection tube(80mm) | 3050 | / | |||
4*25*1.5ml | 2808 | / | |||
No.2 | Swing Rotor Support | 4*250ml | / | / | / |
Hanging Cup | 4*250ml | / | / | / | |
Adapter | 4*1*100ml | 4000 | 2379 | / | |
4*1*50ml | 2379 | / | |||
4*9*10ml | 2379 | / | |||
Tube Rack | 4*4*50ml | 4000 | 3500 | / | |
4*2*50ml(▲) | 3023 | / | |||
4*20*5ml | 3139 | / | |||
4*18*5ml blood collection tube(L106mm) | 2808 | 72*2ml | |||
4*12*5ml blood collection tube(L75mm) | 2808 | / | |||
4*12*5ml blood collection tube(L100mm) | 2808 | 48*2ml | |||
4*12*5ml blood collection tube(L106mm) | 2808 | 48*2ml | |||
4*10*5ml blood collection tube(L106mm) | 2808 | 40*2ml | |||
No.3 | Swing Rotor Support | SUS304 Support | / | / | / |
Hanging Basket | 4*2*100ml | 4000 | 3175 | / | |
4*1*100ml | 3007 | / | |||
4*2*50ml | 3022 | 50ml(▲), 15ml(●) | |||
4*1*50ml | 2846 | ||||
4*8*15ml | 3030 | 15ml(▲), 10ml(▲), 10ml blood collection tube, 5ml blood collection tube, 2ml blood collection tube(L75) | |||
4*6*15ml | 2705 | ||||
4*4*15ml | 2705 | ||||
4*8*10ml | 3030 | / | |||
4*6*10ml | 2705 | / | |||
4*4*10ml | 2705 | / | |||
No.4 | Microplate Rotor | 2*2*96well | 4000 | 2300 | / |
No.5 | Angle Rotor | 12*10ml | 5000 | 3440 | 12*5ml |
No.6 | Angle Rotor | 18*10ml | 5000 | 3516 | 18*5ml |
No.7 | Angle Rotor | 24*10ml | 5000 | 3516 | 24*5ml |
No.8 | Angle Rotor | 8*15ml | 5000 | 3300 | / |
No.9 | Angle Rotor | 12*15ml | 5000 | 3438 | / |
No.10 | Angle Rotor | 12*20ml | 5000 | 3360 | / |
No.11 | Angle Rotor | 4*50ml | 5000 | 3400 | / |
No.12 | Angle Rotor | 6*50ml | 5000 | 3281 | / |
No.13 | Angle Rotor | 4*100ml | 4000 | 2100 | / |
Note: The default is round-bottom tube, with mark (▲) is sharp-bottom tube. The swing rotor should select support+hanging cup+adapter or support+tube rack.