BK-2000
BIOBASE
Features:
1. 300 sample positions.
2. 432 reaction cuvettes.
3. 250 refrigerated reagent positions.
4. Double focus, double aperture, holographic concave grating.
5. 2000 tests per hour, ISE is optional.
6. Built-in sample barcode system.
7. Probe with anti-collision function, liquid level detection function.
Technical Parameters:
Model | BK-2000 | |
Overall | Throughput | 2000 tests/hour, ISE(Optional) |
Analysis Method | End-point, Fixed-time, Rate(Kinetic), Turbidimetry | |
Certificates | CE, FDA, ISO9001, ISO14001, ISO13485 | |
Sample&Reagent System | Sample Positions | 300 sample positions |
Reagent Positions | 250 reagent positions | |
Sample Volume | 1~35μl | |
Reagent Volume | 1~350μl | |
Probe | Teflon coating, with anti-collision function, liquid level detection function | |
Probe Washing | Automatic washing interior and exterior | |
Reagent Cooling | Refrigerated tray with independent switch | |
Reaction System | Temperature Control | Water bath 37±0.1℃, real-time monitoring |
Cuvettes | 432 reusable cuvettes, optical length 5.5mm | |
Mixer Probe | Independent stirring | |
Washing | Automatic cuvettes washing | |
STAT function | YES | |
Optical System | Light Source | 12V/50W halogen lamp/holographic concave grating |
Spectrophotometry | Post-spectral spectrophotometry | |
Wavelength | 16 wavelength from 340~850nm | |
Absorbance | 0~3.5Abs | |
Calibration&QC | Calibration | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Ogarithm, Logit-4P, Logit-5P |
Quality Control | Real-time QC, Westgard Multi Rule, Cumulative Sum Check, Twin Plot(2D) | |
Data Management | Software | Windows 7/8/10, 32 or 64 bit |
LIS System | Bi-direction, support HL7 protocol | |
Interface | LAN port access | |
Printer | External, multiple reporting mode available | |
Working Conditions | Power Supply | AC220V±10%, 50/60Hz(Standard) 110V±10%, 60Hz(Optional), 3000W |
Temperature | 15~30℃(±2 ℃) | |
Water Consumption | Deionized water: 80L/H | |
Humidity | 40~85% | |
Size&Weight | External Size (W*D*H) | Scheduling module: 972*1225*1495mm Analysis module: 1505*1225*1245mm |
Net Weight | Scheduling module: 160kg Analysis module: 500kg | |
Package Size (W*D*H) | Scheduling module: 1410*1350*1170mm Analysis module: 1685*1410*1460mm | |
Gross Weight | Scheduling module: 235kg Analysis module: 600kg |
Features:
1. 300 sample positions.
2. 432 reaction cuvettes.
3. 250 refrigerated reagent positions.
4. Double focus, double aperture, holographic concave grating.
5. 2000 tests per hour, ISE is optional.
6. Built-in sample barcode system.
7. Probe with anti-collision function, liquid level detection function.
Technical Parameters:
Model | BK-2000 | |
Overall | Throughput | 2000 tests/hour, ISE(Optional) |
Analysis Method | End-point, Fixed-time, Rate(Kinetic), Turbidimetry | |
Certificates | CE, FDA, ISO9001, ISO14001, ISO13485 | |
Sample&Reagent System | Sample Positions | 300 sample positions |
Reagent Positions | 250 reagent positions | |
Sample Volume | 1~35μl | |
Reagent Volume | 1~350μl | |
Probe | Teflon coating, with anti-collision function, liquid level detection function | |
Probe Washing | Automatic washing interior and exterior | |
Reagent Cooling | Refrigerated tray with independent switch | |
Reaction System | Temperature Control | Water bath 37±0.1℃, real-time monitoring |
Cuvettes | 432 reusable cuvettes, optical length 5.5mm | |
Mixer Probe | Independent stirring | |
Washing | Automatic cuvettes washing | |
STAT function | YES | |
Optical System | Light Source | 12V/50W halogen lamp/holographic concave grating |
Spectrophotometry | Post-spectral spectrophotometry | |
Wavelength | 16 wavelength from 340~850nm | |
Absorbance | 0~3.5Abs | |
Calibration&QC | Calibration | Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Ogarithm, Logit-4P, Logit-5P |
Quality Control | Real-time QC, Westgard Multi Rule, Cumulative Sum Check, Twin Plot(2D) | |
Data Management | Software | Windows 7/8/10, 32 or 64 bit |
LIS System | Bi-direction, support HL7 protocol | |
Interface | LAN port access | |
Printer | External, multiple reporting mode available | |
Working Conditions | Power Supply | AC220V±10%, 50/60Hz(Standard) 110V±10%, 60Hz(Optional), 3000W |
Temperature | 15~30℃(±2 ℃) | |
Water Consumption | Deionized water: 80L/H | |
Humidity | 40~85% | |
Size&Weight | External Size (W*D*H) | Scheduling module: 972*1225*1495mm Analysis module: 1505*1225*1245mm |
Net Weight | Scheduling module: 160kg Analysis module: 500kg | |
Package Size (W*D*H) | Scheduling module: 1410*1350*1170mm Analysis module: 1685*1410*1460mm | |
Gross Weight | Scheduling module: 235kg Analysis module: 600kg |